HI-6553/P pH/ORP/ISE + EC + Polarographic DO Multiparameter Modular Benchtop Meter

£1,395.00 (exc VAT) each

Download Product Page PDF
SKU: HI-6553P-02 Categories: , , ,

This kit includes the necessary modules and probes to measure pH, temperature, conductivity and dissolved oxygen with a polarographic probe, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity.

HI-6553P-02 pH/ORP/ISE + EC + Polarographic DO Kit
Range -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
Resolution 0.1 pH; 0.01 pH; 0.001 pH
Accuracy ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)
Temperature Compensation Automatic or manual
mV
Range -2000.0 mV to 2000.0 mV
Resolution 1 mV; 0.1 mV
Accuracy ±0.2 mV ±1 last significant digit
ISE
Range 1 x 10-6 to 9.99 x 1010 concentration
Resolution 1; 0.1; 0.01; 0.001 concentration
Accuracy ±0.5% (monovalent ions); ±1% (divalent ions)
Calibration Automatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards
Temperature
Range -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K
Resolution 0.1 °C / 0.1 °F / 0.1 K
Accuracy ±0.2 °C / ±0.4 °F / ±0.2 K
Relative mV offset range ±2000.0 mV
pH Calibration
Calibration points Up to 5
Type Automatic; Semiautomatic; Manual
Standard buffers Hanna and NIST – pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45
Custom buffers Up to 5
Custom group Up to 5
1st calibration point Offset or Points (user setting)
Temperature User Calibration Single point, adjustable; Isopotential point: -2.000 to 20.000pH
Conductivity
Range 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm;
1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm
Resolution 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Accuracy ±1 % of reading ±0.010 μS/cm, whichever is greater
Cell Constant 0.0500 to 200.00 /cm
Calibration Type automatic; manual
Calibration points Single
Multiple
Calibration solutions 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm
Temperature Compensation Linear, natural, standard, disabled
Reference Temperature Range: 5.0 to 30.0˚C (41.0 to 86.0˚C
Resolution 0.1˚C / 0.1˚F
Temperature Coefficient 0.00 to 10.00%/˚C
Resistivity
Range 1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm
Resolution 0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm
Accuracy ±1 % of reading or ±1 Ω・cm, whichever is greater
Total Dissolved Solids (TDS)
Range 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)
Resolution 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
Accuracy ±1 % of reading or ±0.01 ppm, whichever is greater
Salinity
Range 0.00 to 42.00 PSU – Practical Scale
0.00 to 80.00 ppt – Natural Sea Water
0.0 to 400.0 % – Percent Scale
Resolution 0.01 for Practical Scale / Natural Sea Water
0.1 % for Percent Scale
Accuracy ±1 % of reading
Calibration 1 point for Percent Scale, using 100% salinity calibration solution
Temperature
Range −20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K
Resolution 0.1 °C; 0.1 °F; 0.1 K
Accuracy ±0.2 °C; ±0.4 °F; ±0.2 K
Calibration Single point, adjustable
Dissolved Oxygen
Range 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0 % saturation
Resolution 0.01 mg/L (ppm); 0.1 % saturation
Accuracy Refer to individual specifications for probe used
HI-764833 Polarographic probe
Range 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0 % saturation
Resolution 0.01 mg/L (ppm); 0.1 % saturation
Accuracy ±1.5 % of reading ±1, least significant digit
Barometric Pressure
Range 450 to 850 mmHg; 600 to 1133 mBar; 60 to 113.32 kPa;
17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.592 to 1.1184 atm
Resolution 1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm
Accuracy ±3 mmHg within ±15 % from the calibration point
±3 mmHg ±1 least significant digit
Temperature
Range −20.0 to 120.0 °C
−4.0 to 248.0 °F
253.0 to 393.0 K
Resolution 0.1 °C; 0.1 °F; 0.1 K
Accuracy Refer to specification of probe used
DO Calibration
Points One or two points at 100.0% (8.26 mg/L) and 0.0% (0.00 mg/L) automatic.
Manual using a value entered by the user in % saturation, mg/L or ppm.
Temperature User Calibration 1 point, configurable
Salinity Compensation Manual; 0.00 to 45.00 PSU or ppt
0.0 to 130.0 %