This kit includes the necessary modules and probes to measure pH, temperature, conductivity and dissolved oxygen with an optical probe, providing everything needed to start measuring straight out of the box. This advanced multimeter features WiFi and ethernet connectivity.
| HI-6553-02 pH/ORP/ISE + EC + Optical (opdo®) DO Kit | ||
| Range | -2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH | |
| Resolution | 0.1 pH; 0.01 pH; 0.001 pH | |
| Accuracy | ±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit) | |
| Temperature Compensation | Automatic or manual | |
| mV | ||
| Range | -2000.0 mV to 2000.0 mV | |
| Resolution | 1 mV; 0.1 mV | |
| Accuracy | ±0.2 mV ±1 last significant digit | |
| ISE | ||
| Range | 1 x 10-6 to 9.99 x 1010 concentration | |
| Resolution | 1; 0.1; 0.01; 0.001 concentration | |
| Accuracy | ±0.5% (monovalent ions); ±1% (divalent ions) | |
| Calibration | Automatic, up to five-point calibration, seven fixed standard solutions available for each measurement unit, and five user defined standards | |
| Temperature | ||
| Range | -20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K | |
| Resolution | 0.1 °C / 0.1 °F / 0.1 K | |
| Accuracy | ±0.2 °C / ±0.4 °F / ±0.2 K | |
| Relative mV offset range | ±2000.0 mV | |
| pH Calibration | ||
| Calibration points | Up to 5 | |
| Type | Automatic; Semiautomatic; Manual | |
| Standard buffers | Hanna and NIST – pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 | |
| Custom buffers | Up to 5 | |
| Custom group | Up to 5 | |
| 1st calibration point | Offset or Points (user setting) | |
| Temperature User Calibration | Single point, adjustable; Isopotential point: -2.000 to 20.000pH |
| Conductivity | |
| Range | 0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
| Resolution | 0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
| Accuracy | ±1 % of reading ±0.010 μS/cm, whichever is greater |
| Cell Constant | 0.0500 to 200.00 /cm |
| Calibration Type | automatic; manual |
| Calibration points | Single Multiple |
| Calibration solutions | 84.00 μS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm |
| Temperature Compensation | Linear, natural, standard, disabled |
| Reference Temperature | Range: 5.0 to 30.0˚C (41.0 to 86.0˚C Resolution 0.1˚C / 0.1˚F |
| Temperature Coefficient | 0.00 to 10.00%/˚C |
| Resistivity | |
| Range | 1.0 to 99.9 Ω・cm; 100 to 999 Ω・cm; 1.00 to 9.99 KΩ・cm; 10.0 to 99.9 KΩ・cm; 100 to 999 KΩ・cm; 1.00 to 9.99 MΩ・cm; 10.0 to 100.0 MΩ・cm |
| Resolution | 0.1 Ω・cm; 1 Ω・cm; 0.01 KΩ・cm; 0.1 KΩ・cm; 1 KΩ・cm; 0.01 MΩ・cm; 0.1 MΩ・cm |
| Accuracy | ±1 % of reading or ±1 Ω・cm, whichever is greater |
| Total Dissolved Solids (TDS) | |
| Range | 0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
| Resolution | 0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
| Accuracy | ±1 % of reading or ±0.01 ppm, whichever is greater |
| Salinity | |
| Range | 0.00 to 42.00 PSU – Practical Scale 0.00 to 80.00 ppt – Natural Sea Water 0.0 to 400.0 % – Percent Scale |
| Resolution | 0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale |
| Accuracy | ±1 % of reading |
| Calibration | 1 point for Percent Scale, using 100% salinity calibration solution |
| Temperature | |
| Range | −20.0 to 120.0 °C; -4.0 to 248.0˚F; 253.0 to 393.0 K |
| Resolution | 0.1 °C; 0.1 °F; 0.1 K |
| Accuracy | ±0.2 °C; ±0.4 °F; ±0.2 K |
| Calibration | Single point, adjustable |
| Dissolved Oxygen | ||
| Range | 0.00 to 90.00 mg/L (ppm) concentration; 0.0 to 600.0 % saturation | |
| Resolution | 0.01 mg/L (ppm); 0.1 % saturation | |
| Accuracy | Refer to individual specifications for probe used | |
| HI-7641133 DO Probe Specification | ||
| Probe Body Material | ABS | |
| Smart Cap™ material | Polypropylene | |
| Cable jacket material | PVC | |
| Cable Length | 1m | |
| probe guard | Stainless steel | |
| Temperature Measurement | Thermistor | |
| Pressure | 20m (29 PSI) | |
| Probe Dimensions with guard | 174 x 25mm | |
| Response Time | 45 seconds | |
| probe ingress protection rating | IP68 | |
| Sensor type | Optical; luminescence quenching |